In each case you can choose from 20+ sensors (including LEL-IR, LEL-MPS, PID, NH3, CO, H2S, O2, CO2, Cl2, etc.). The Blackline G8 always has an adjustable low gas alarm, high gas alarm, 15-minute rolling average (STEL) and a working-day average (TWA).
As soon as a limit value for gases is exceeded, the device beeps and flashes locally. A notification of the location and gas reading is also sent to the Blackline Live portal. That way a colleague immediately has insight into how serious the situation is. In emergencies the Blackline G8 can be called directly to check whether everything is all right. If there is no answer, the colleague knows straight away which gas and which concentrations are present, and whether a gas mask is needed during a rescue operation, for example.
Real-time measurement data streams automatically in the background over 4G LTE to Blackline Live: the cloud platform for 24/7 monitoring, alert management, location maps, event history and big data analytics. Bump test reports, completed calibrations and gas exposure data are available automatically, including downloadable certificates for audits.As soon as one of the sensors above is triggered, a pre-alarm goes off first. This alarm is only on the device itself and is therefore not forwarded to a colleague. The duration of the pre-alarm is adjustable, 30 seconds for example. Should the wearer of the Blackline G8 not (be able to) respond to the pre-alarm, for instance because they have lost consciousness after the fall, the alarm is forwarded to a colleague or a monitoring agency via the Blackline Live portal.
Li-ion battery: 1350 mAh, up to 18 hours (typical in diffusion mode at 20 °C, with LEL-IR/MPS + H2S/CO/O2)
Charging time: 4 hours
Ammonia (NH₃)
sensor type: electrochemical
range: 0–100 ppm
resolution: 0.1 ppm
High-Range Ammonia (NH₃)
sensor type: electrochemical
range: 0–500 ppm
resolution: 1 ppm
Carbon Dioxide (CO₂)
sensor type: NDIR
range: 0–50,000 ppm
resolution: 50 ppm
Carbon Monoxide (CO)
sensor type: electrochemical
range: 0–500 ppm
resolution: 1 ppm
High-Range Carbon Monoxide (CO)
sensor type: electrochemical
range: 0–2000 ppm
resolution: 1 ppm
Hydrogen-Resistant Carbon Monoxide (CO-H)
sensor type: electrochemical
range: 0–500 ppm
resolution: 1 ppm
Chlorine (Cl₂)
sensor type: electrochemical
range: 0–20 ppm
resolution: 0.1 ppm
note: not compatible with pump cartridge
Chlorine Dioxide (ClO₂)
sensor type: electrochemical
range: 0–2 ppm
resolution: 0.01 ppm
note: not compatible with pump cartridge
COSH (CO & H₂S)
sensor type: electrochemical
range: 0–500 ppm CO / 0–200 ppm H₂S
resolution: 1 ppm CO / 0.1 ppm H₂S
High-Range Hydrogen Sulfide (H₂S)
sensor type: electrochemical
range: 0–500 ppm
resolution: 0.5 ppm
Hydrogen Sulfide (H₂S)
sensor type: electrochemical
range: 0–100 ppm
resolution: 0.1 ppm
Hydrogen (H₂) (outside North America)
sensor type: electrochemical
range: 0–40,000 ppm
resolution: 1% LEL (400 ppm H₂)
Hydrogen Cyanide (HCN)
sensor type: electrochemical
range: 0–30 ppm
resolution: 0.1 ppm
Hydrogen Fluoride (HF)
sensor type: electrochemical
range: 0–10 ppm
resolution: 0.1 ppm
note: not compatible with pump cartridge
Nitrogen Dioxide (NO₂)
sensor type: electrochemical
range: 0–50 ppm
resolution: 0.1 ppm
Oxygen (O₂)
sensor type: pumped electrochemical
range: 0–25% vol
resolution: 0.1% vol
Ozone (O₃)
sensor type: electrochemical
range: 0–1 ppm
resolution: 0.01 ppm
note: not compatible with pump cartridge
Photoionization (PID)
sensor type: PID
range: 0–4,000 ppm
resolution: variable (lowest 0.1 ppm)
note: depends on correction factor
Sulfur Dioxide (SO₂)
sensor type: electrochemical
range: 0–100 ppm
resolution: 0.1 ppm
LEL-Infrared (LEL-IR)
sensor type: NDIR
range: 0–100% LEL
resolution: 1% LEL
LEL-MPS
sensor type: MPS
range: 0–100% LEL
resolution: 1% LEL
note: operating pressure 80–120 kPa
Wide range
Enjoyment, safety and health
Helpful
Rental, sales and maintenance
Tell us what you are looking for and we will help you on your way.
Contact
BaSystemen BV
Protonstraat 13G
9743 AL Groningen, The Netherlands
+31505712124
info@basystemen.nl
Opening hours
Monday 08:00–17:30
Tuesday 08:00–17:30
Wednesday 08:00–17:30
Thursday 08:00–17:30
Friday 08:00–17:30
Saturday Closed
Sunday Closed
In urgent cases we are also reachable outside opening hours on +31 (0)50-5712124
Copyright 2026 BaSystemen B.V.