The SV 977D is an advanced class 1 sound and vibration level meter, developed for accurate measurements in building acoustics, working environments and environmental monitoring. Thanks to the combination of sound, ultrasound and vibration measurements in one rugged device, the SV 977D is a versatile solution for professionals who need extensive analysis functionality in a single compact unit.
The device comes as standard with a ½” MK 255 microphone, which covers a frequency range from 3 Hz to 20 kHz and offers excellent stability. For specific applications, such as ultrasound analysis in industrial or medical contexts, the meter offers a measuring range up to 40 kHz.
The SV 977D records both sound and vibration. Combined with a vibration sensor, the system complies with ISO 20816-1 as a Class 1 vibration meter. The device supports 1/1 and 1/3 octave band analysis, real-time spectrum measurement and time-domain recording in WAV format, enabling detailed post-processing in software such as SvanPC++.
The SV 977D is the right choice when you need a compact, versatile class 1 meter for sound, vibration and ultrasound measurements alike. This model is ideal for professionals in building acoustics, occupational safety and environmental measurement who work to ISO standards and need Bluetooth connectivity, mobile apps and long field autonomy. Thanks to the wide frequency range up to 40 kHz and the option of vibration measurement, the SV 977D combines several functions in a single device — perfect for efficient, mobile use without compromising on accuracy.
The SV 977D is particularly suitable when you are looking for an all-in-one solution that:
Can measure both sound and vibration accurately,
Requires ultrasound measurements up to 40 kHz (e.g. for leak detection or medical equipment)
Supports wireless working in the field via Bluetooth and apps
Offers full compatibility with building acoustics standards, including RT60 and STIPA.
Choose the SVAN 979 instead of the SV 977D if you:
Need to measure even lower sound levels (such as in studios or quiet environments). The SV 977D has a measuring range of 16 dBA – 140 dBA Peak, whereas the SVAN 979 achieves an even lower range from 12 dBA – 140 dBA Peak.
Need more detailed spectrum analysis such as 1/6 or 1/12 octave bands
Want to carry out tonality analysis or other specialised acoustic parameters
Choose the SV 971A if you:
Only carry out basic sound measurements (e.g. for occupational health and safety or machine inspections), and have no need for vibration and/or ultrasound.
4x AA rechargeable battery, 8 operating hours
Class: IEC 61672-1:2013 Class 1
Linear measuring range (in accordance with IEC 61672): 23 dBA Leq ÷ 140 dBA Peak
Total measuring range: 16 dBA Leq ÷ 140 dBA Peak
Self-noise (internal noise): <16 dB(A) LAeq
Frequency range: 3 Hz ÷ 20 kHz (up to 40 kHz for ultrasound analysis)
Frequency weightings: A, B, C, Z, LF, U, AU
Time constants: Slow, Fast, Impulse
Number of sound profiles per channel: 3
Minimum logging interval: 2 ms
Statistics: Ln (L1 – L99)
Statistics per octave / third octave: Yes
1/1 octave band analysis: Yes
1/3 octave band analysis: Yes
FFT analysis: Optional
Audio recording (WAV): Optional
RT60 (reverberation time): Optional
STIPA (speech intelligibility): Optional
Speed measurement (RPM): Optional
Wide range
Enjoyment, safety and health
Helpful
Rental, sales and maintenance
Tell us what you are looking for and we will help you on your way.
Contact
BaSystemen BV
Protonstraat 13G
9743 AL Groningen, The Netherlands
+31505712124
info@basystemen.nl
Opening hours
Monday 08:00–17:30
Tuesday 08:00–17:30
Wednesday 08:00–17:30
Thursday 08:00–17:30
Friday 08:00–17:30
Saturday Closed
Sunday Closed
In urgent cases we are also reachable outside opening hours on +31 (0)50-5712124
Copyright 2026 BaSystemen B.V.